Reference articles on history, science, culture and more
Encyclopedia

Back-Up Interceptor Control

Computer backup system

01Background

Prior to the SAGE Direction Centers becoming operational, the USAF deployed data link systems at NORAD Control Centers with ground computers for controlling crewed interceptors. After SAGE IBM AN/FSQ-7 Combat Direction Centrals became operational and the Super Combat Centers with improved (digital) computers were cancelled, a backup to SAGE was planned in the event the above-ground SAGE Air Defense Direction Center failed.

BUIC III at North Turro AFS shortly before shutdown December 1973. Background l->r Cabinets Memory 5&6, Memory 7&8, Computer 1, Computer 2. Foreground: Status Display Console, Teletype. Cabinets are about 3' wide, 3' deep, & 7' high
BUIC III at North Turro AFS shortly before shutdown December 1973. Background l->r Cabinets Memory 5&6, Memory 7&8, Computer 1, Computer 2. Foreground: Status Display Console, Teletype. Cabinets are about 3' wide, 3' deep, & 7' high

02General Electric AN/GPA-37 Course Directing Group

BUIC began with deployment of General Electric AN/GPA-37 Course Directing Groups to several Long Range Radar stations. Units designated included the "U.S. Air Force 858th Air Defense Group (BUIC) [which became] a permanent operating facility" at Naval Air Station Fallon in Nevada.

03BUIC II

BUIC II was used to command and control sites using the Burroughs AN/GSA-51 Radar Course Directing Group. North Truro AFS became the first ADC installation configured for BUIC II.

04BUIC III

The AN/GYK-19 (initially AN/GSA-51A) was an upgraded version of the BUIC II system designated AN/GSA-51A and required a larger building than the AN/GSA-51. The first BUIC III site was Fort Fisher AFS, and Air Defense Command's was first installed at Fort Fisher Air Force Station, North Carolina.

Although more advanced systems were contemplated, the final design of the BUIC III system was an upgraded version of the BUIC II with around twice the performance.

05Closure and upgrade

In 1972, the USAF decided to shut down most of the BUIC sites; most of the sites mothballed by 1974, except for the BUIC III site at Tyndall Air Force Base. In Canada the BUIC site at Senneterre was shut down, but St Margarets remained open. The remaining sites were closed between 1983-1984 when SAGE was replaced by the Joint Surveillance System.

The AN/FYQ-47 Common Digitizer for the Joint Surveillance System, and the Radar Video Data Processor (RVDP) was a combined system for the Air Force and Federal Aviation Administration (FAA), it replaced the SAGE Burroughs AN/FST-2 Coordinate Data Transmitting Sets.

Watch videos about Back-Up Interceptor ControlExplainers and documentaries on YouTube (opens in a new tab)

Sources and credits

This article is adapted from the Wikipedia article Back-Up Interceptor Control, written by its contributors and licensed under CC BY-SA 4.0. Fathomly has changed the layout, removed citation markers, navigation and maintenance notices, and adjusted punctuation. This adapted version is shared under the same license. For references, see the original article.

Images, from Wikimedia Commons:

Fathomly is not affiliated with or endorsed by the Wikimedia Foundation. Spotted a problem? Tell us.